Technical specifications
|
DMR.731
|
|
Output channels.
|
1 |
|
Μaximum Οutput power.
|
350 W |
|
Μinimum Οutput power.
|
0 W |
|
Operation mode.
|
Trailing edge |
|
Load types.
|
Dimmable 230V LED lamps. Dimmable compact fluorescent lamps. (CFL). 230V halogen lamps. Electronic transformers for low voltage halogen lamps. Incandescent lamps. |
|
Digital input
|
DMX-512 / 1990. |
|
Digital output
|
DMX-512 / 1990. (Through). |
|
Analog input.
|
Yes. |
|
Analogue input operation modes.
|
1) 0-10V or 1-10V, 2) Single push button, 3) Up-down push buttons (Two buttons). |
|
Enhanced operation 1-10V.
|
1) Yes. When dimmer controlled from 1-10V controller, (not rheostat), 0-100% dimming can be selected. 2) When rheostat is used, dimming range is 0-100%. |
|
Analogue and digital Merge modes.
|
HTP or LAST (aller retour), selectable. |
|
Master / Slave operation.
|
Yes. Slave dimmers take control from master dimmer via digital connection. |
|
Dimming Law correction.
|
Yes. Adjusting the built-in min and max trimmers user can achieve dimming without control, the intervals. |
|
Dimming resolution.
|
2040 steps. |
|
Off @ minimum.
|
Yes. Selectable. When minimum level is set at 10% e.g., the user can select if dimmer will turn off at 0% of control input. |
|
CFL ignition.
|
Yes. When turning on dimmer with low dimming level, CFLs may not turn on at that level. With CFL ignition is selected, the dimmer automatically inserts 1sec. 100% output voltage pulse, for proper CFL turn on. |
|
PWM signal output.
|
Yes. Connecting to this output ELECTRON'S constant voltage, constant current converters or boosters, the user can control at the same time different types of LED fixtures. |
|
PWM signal output voltage.
|
24V |
|
PWM signal output current.
|
80 mA |
|
Power supply voltage.
|
230VAC (-25%, +15%) / 50Hz |
|
Power consumption. (Max load at 100%).
|
353 W |
|
Power consumption. (Max load at 0%).
|
< 1W |
|
Output current.
|
1,52A rms |
|
Ambient temperature.
|
0°C to 40°C |
|
Dimensions (L x W x H)
|
248,5mm x 49mm x 43,2mm |